INSTALLATION INSTRUCTIONS
READ & SAVE THESE INSTRUCTIONS!
IMPORTANT SAFETY INSTRUCTIONS
WARNING: TO REDUCE THE RISK OF FIRE. ELECTRIC
SHOCK, OR INJURY TO PERSONS, OBSERVE THE
FOLLOWING:
A. Use this unit only in the manner intended by the manufacturer. 
If you have questions, contact the manufacturer.
B. Before servicing or cleaning unit, switch power off at service 
panel and lock service panel to prevent power from being 
switched on accidentally. 
When the service disconnecting means cannot be locked, 
securely fasten a prominent warning device, such as a tag, to 
the service panel.
CAUTION:
For general ventilating use only. Do not use to exhaust 
hazardous or explosive materials and vapors.
INSTALLATION INSTRUCTIONS
WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC
SHOCK, OR INJURY TO PERSONS, OBSERVE THE
FOLLOWING:
A. Installation work and electrical wiring must be done by 
qualified person(s) in accordance with all applicable codes and 
standards, including fire-rated construction.
B. Sufficient air is needed for proper combustion and exhausting 
of gases through the flue (chimney) of fuel burning equipment 
to prevent back drafting. Follow the heating equipment 
manufacturer’s guideline and safety standards such as those 
published by the National Fire Protection Association (NFPA), 
and the American Society for Heating, Refrigeration and 
Air Conditioning Engineers (ASHRAE), and the local code 
authorities.
C. When cutting or drilling into wall or ceiling, do not damage 
electrical wiring and other hidden utilities.
D. Ducted fans must always be vented to the outdoors.
E. If this unit is to be installed over a tub or shower, it must be 
marked as appropriate for the application.
F. NEVER place a switch where it can be reached from a tub or 
shower.
WARNING:To reduce the risk of fire or electric shock, do not 
use this fan with any solid-state speed control.
 Not for use in kitchens.
  Suitable for use over tub or shower when installed in a GFI 
(or GFCI) Protected Branch Circuit.
•  Do not install in a ceiling insulated to a value greater than R-40.
  The exhaust fan consists of the housing, power unit/blower 
assembly (motor, wheel, mounting plate,) grille and duct collar.
Ventilation Fan
MODEL: 8814R
SUITABLE FOR USE OVER TUB OR SHOWER ENCLOSURE
WHEN INSTALLED IN A GFCI PROTECTED BRANCH CIRCUIT.
FOR BEST RESULTS
When installing the exhaust fan in a new construction site, 
install housing during the rough-in construction of the building. 
The blower unit and grille should be installed after the finished 
ceiling is in place.
To install the exhaust fan in an existing finished building 
requires an accessible area (attic or crawl space) above the 
planned location.
PLANNING DUCTWORK AND WIRING
DUCTWORK
1. Use 4” round duct.
2. Plan to run duct from discharge opening of fan to the outside. 
For best fan performance, make duct run as short as possible.
3. Use optional NuTone ducting accessories as needed. Refer 
to your NuTone catalog for a complete listing of available 
accessories.
WIRING
Plan to run 120vAC house wiring (with ground) from power 
source, through a standard wall switch to junction box in fan 
housing.
FIGURE 1
DUCT
COLLAR
HOUSING
SLOTS
POWER UNIT/
BLOWER
ASSEMBLY
TABS
GRILLE
TO REGISTER THIS PRODUCT, VISIT WWW.NUTONE.COM
Vue de la page 0
1 2 3 4 5 6 7 8 9 10

Résumé du contenu

Page 1 - Ventilation Fan

INSTALLATION INSTRUCTIONSREAD & SAVE THESE INSTRUCTIONS!IMPORTANT SAFETY INSTRUCTIONS    WARNING: TO REDUCE THE RISK OF FIRE. ELECTRIC SHOCK, OR I

Page 2 - PREPARATION

KEY NO. PART NO. DESCRIPTION1  101255-000  MOTOR MOUNTING PLATE2  32787-000  MOTOR ISOLATION MOUNT3  32788-000  GROUND CLIP4  100599-000  MOTOR5  10

Page 3 - EXISTING CONSTRUCTION

INSTALLATION IN A NEW CONSTRUCTION SITEPREPARATIONRefer to Figure 1.1.  To remove blower/power unit assembly from housing:    A.  Unplug power unit. 

Page 4 - Ventilateur de

INSTALLATION IN EXISTING CONSTRUCTIONNote: Installation in a finished house requires an accessible area (attic or crawl space) above the planned inst

Page 5 - INSTALLATION DE LA GAINE

INSTRUCTIONS D’INSTALLATIONLIRE ET CONSERVER CES INSTRUCTIONSIMPORTANTES DIRECTIVES DE SÉCURITÉAVERTISSEMENT: POUR RÉDUIRE LES RISQUES D’INCENDIE, DE

Page 6 - INSTALLATION DU MOTEUR

INSTALLATION DANS UNE CONSTRUCTION NEUVEPREPARATION1. Voir Figure 1. Enlever le bloc-moteur du boîtier.  A.  Débrancher le moteur.  B.   Enlever et co

Page 7 - Ventilador de

FIGURE 5RESSORTS DE MONTAGEINSERRER LES PATTES DANS LES FENTESGRILLEINSTALLATION DU MOTEUR1.  Placer le moteur dans le boîter de telle sorte que  les 

Page 8 - ALAMBRADO

INSTRUCCIONES DE INSTALACION¡LEA Y GUARDE ESTAS INSTRUCCIONES!INSTRUCCIONES IMPORTANTES DE SEGURIDAD ADVERTENCIA: PARA REDUCIR EL RIESGO DE INCENDI

Page 9 - CONSTRUIDO

INSTALACION EN UN NUEVO EDIFICIO EN CONSTRUCCIONPREPARACIONVea la Figura 1.1.   Para remover del bastidor el ensamblaje de la unidad de poder/soplador

Page 10 - SERVICE PARTS

INSTALACION DE LA UNIDAD DE PODER/SOPLADOR 1.   Coloque la unidad de poder/soplador dentro del bastidor de manera que las orejas del plato de montaje 

Commentaires sur ces manuels

Pas de commentaire