MODEL 745BNNT
DECORATIVE VENTILATION
FAN WITH LIGHT
READ AND SAVE THESE INSTRUCTIONS
TYPICAL INSTALLATIONS
HOUSING
MOUNTING TABS
POWER CABLE
GRILLE
PAN
GLASS
LIGHT SHADE
CEILING
JOIST
CEILING
MATERIAL
HOUSING
HOUSING MOUNTED
DIRECTLY TO JOIST
2x6 (or larger)
Discharge parallel to joists.
HOUSING
2 x 4
CEILING
JOIST or
TRUSS
MOUNTING
TABS
POWER CABLE
ADDITIONAL
FRAMING
2 x 4
CEILING
JOIST or
TRUSS
GRILLE
PAN
GLASS
LIGHT SHADE
CEILING
MATERIAL
HOUSING MOUNTED
TO 2x4 TRUSS
Requires additional framing
for mounting tabs.
Discharge parallel to joists.
HOUSING
MOUNTING
TABS
POWER CABLE
ADDITIONAL
FRAMING
"
I
"
JOIST
"
I
"
JOIST
GRILLE
PAN
GLASS LIGHT SHADE
CEILING
MATERIAL
HOUSING MOUNTED TO “I” JOIST
Requires additional framing
for mounting tabs.
Discharge parallel to joists.
*
Additional framing must be a 2x6 (minimum height), at least 9-inches long.
*
*
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR
INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufac-
turer. If you have questions, contact the manufacturer at
the address or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at
service panel and lock the service disconnecting means
to prevent power from being switched on accidentally.
When the service disconnecting means cannot be locked,
securely fasten a prominent warning device, such as a
tag, to the service panel.
3. Installation work and electrical wiring must be done by
a qualified person(s) in accordance with all applicable
codes and standards, including fire-rated construction
codes and standards.
4. Sufficient air is needed for proper combustion and
exhausting of gases through the flue (chimney) of fuel
burning equipment to prevent backdrafting. Follow the
heating equipment manufacturer’s guideline and safety
standards such as those published by the National Fire
Protection Association (NFPA), and the American Society
for Heating, Refrigeration and Air Conditioning Engineers
(ASHRAE), and the local code authorities.
5. When cutting or drilling into wall or ceiling, do not dam-
age electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. DO NOT install in a tub or shower enclosure.
8. This unit must be grounded.
9. This unit
is U.L. listed. Type I.C. inherently protected.
CAUTION
!
1. For general ventilating use only. Do not use to exhaust
hazardous or explosive materials and vapors.
2. This product is designed for installation in FLAT CEILINGS
ONLY. Do not mount this product in a wall.
3. The light fixture assembly must be mounted to the fan
housing assembly included with this product. Do not
mount the light fixture assembly to a wiring outlet box.
4. To avoid motor bearing damage and noisy and/or unbal-
anced impellers, keep drywall spray, construction dust,
etc. off power unit.
5. Please read specification label on product for further
information and requirements.
Installer:
Leave this manual with the
homeowner.
Homeowner:
Use and Care information on page 4.
PLAN THE INSTALLATION
SUSPENDED CEILINGS
Housing hung with wires -
3-point mount.
MOUNTING
TAB
GRILLE
PAN
SUSPENDED
CEILING
MATERIAL
POWER
CABLE
4" ROUND
DUCT
HOUSING
GLASS
LIGHT SHADE
ROOF CAP*
(with built-in
damper)
WALL CAP*
(with built-in
damper)
4-IN. ROUND
ELBOWS*
4-IN. ROUND
DUCT*
FAN
HOUSING
Seal gaps
around
housing.
Seal duct
joints with
tape.
Keep duct
runs short.
INSULATION
(Place around and
over fan housing.)
POWER
CABLE*
*Purchase
separately.
OR
Vue de la page 0
1 2 3 4 5 6 7 8

Résumé du contenu

Page 1 - FAN WITH LIGHT

Page 1MODEL 745BNNT DECORATIVE VENTILATION FAN WITH LIGHTREAD AND SAVE THESE INSTRUCTIONSTYPICAL INSTALLATIONSHOUSINGMOUNTING TABSPOWER CABLEGRILLEPA

Page 2 - INSTALL THE HOUSING

Page 2MODEL 745BNNT 3. Set housing aside and drive nails partially into joist at the top of both key-hole marks.4. Hang housing from nails and pound

Page 3 - GLASS SHADE

Page 3MODEL 745BNNT BLKVENTSWITCHBLUBLKWHTWHTWHTLIGHT(WHITE)GRDVENT(BLACK)UNITSWITCH BOXLIGHTSWITCHLINEINBLKREDWHTGRDSCHEMATIC WIRING DIAGRAMSWITCH B

Page 4 - WARRANTY

Page 4MODEL 745BNNT USE AND CARE USE AND CAREWARNING: DISCONNECT ELECTRICAL POWER SUPPLY AND LOCK OUT SERVICE PANEL BEFORE CLEANING OR SERVICING THIS

Page 5 - PRECAUCIÓN

Página 5MODELO 745BNNT VENTILADOR DECORATIVA CON LA LUZLEA Y CONSERVE ESTAS INSTRUCCIONESINSTALACIONES TÍPICASCUBIERTA MONTADA DIRECTAMENTE EN LA VIG

Page 6 - INSTALACIÓN DE LA CUBIERTA

Página 6MODELO 745BNNT 3. Coloque la cubierta a un lado e introduzca parcialmente los clavos en la vigueta, en la parte superior de ambas marcas de

Page 7 - MODELO 745BNNT

Página 7MODELO 745BNNT INSTALACIÓN DEL SISTEMA DE CONDUCTOSAL RASNOTA: El conector del conducto tiene una aleta compensadora para el regulador de ti

Page 8 - GARANTIA