1. See Figure 27. Fasten the mounting plate to a stud
within three studs (48") of an electrical outlet box.
Measure and mark the wire 10" from the plug (A). Feed
the wire through the top hole in the mounting plate (just
above the circular opening). Snap the molded plug into
the mounting plate as pictured (B). This will keep it secure
and out of harm’s way during drywalling and finishing.
Line up the wire at the previously measured 10" mark with
the strain of relief channel on the back of the mounting
plate. Secure it in place with the supplied wire tie (C).
2. Run the inlet wire to the adjacent electric box. If you must
run wire through a stud, drill directly through the center
of the stud (D).
3. See Figure 28. Place the exposed ends of the two wires
into the electrical box through a strain relief channel (E).
Tighten the strain relief channel (do not overtighten) on
the white sheathing leaving 1⁄2" of this sheathing
exposed inside of the outlet box.
Fold the 6" of black and white wire into the outlet box. Leave
the wires to be connected by the electrician when plug
receptacles are being installed. (Attention: Power tools such
as routers are not recommended for use with the inlet
installation, as removal of drywall with these devices may
cause damage to the mounting plate and/or inlet plug).
4. Once drywall and finishing processes have been
completed, remove molded plug from mounting plate
(with the aid of a slot screwdriver) and snap it into the
wing slot at the back of the inlet (F). (NOTE: molded plug
fits one way only, with the narrow opening at the top).
Insert inlet into the mounting plate and secure inlet to
mounting plate with screws provided.
NOTE: All electrical devices such as the electrified inlet
should be reported to the construction electrician for
listing on the inspection report for building inspection
purposes.
NOTE: Plumb inlet to tubing using NuTone Model CF382S
90° ELL fitting.
D
AE0038
E
D
AE0039
WARNING
All location and installation direct connect
electrified wall valves must conform with all local
and municipal building codes.
!
FIGURE 27
FIGURE 28