NuTone VX550 Guide d'installation Page 18

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 40
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 17
Insert the bottom screw into
the inlet cover and through the
other parts. Give the screw a
few turns until it firmly engages
in the mounting plate. Now,
level and slightly lower the
assembly. Make sure the wall
is sandwiched between the
inner and outer parts—you’ll
be able to feel if mounting
plate is firmly centered on the
inside of the wall.
Hold the inlet in place and gradually tighten down each
screw a little bit at a time. (If you completely tighten down
one screw at a time, the mounting plate may pull away from
the wall at the loose end and slip back into the cutout.)
Complete all your wall inlet installations in this manner.
If your cutouts are accurate, each wall inlet will install more
quickly and easily.
CI370 OR 360 SERIES INLETS
(CF361 OR CF361F ROUGH-IN)
NOTE: If 330 wall inlet is being used refer to Models 330 &
CI335 Series Wall Inlet on next page.
1. If area is clear, cut an inlet opening in the wall
approximately 18" above the floor. Make sure wall
opening and 2½" tube hole line up (Figure 32).
NOTE: If the wall for mounting the Model 360 inlet is less
than 1⁄2", a spacer must be used. See Figure 23 on page 9
as a guide.
2. Cut a length of tubing that will extend from inlet opening
to a point below floor level (or above ceiling level in attic
installation). Tape low voltage wire to tube and insert
tube through predrilled hole to a level opposite the wall
opening.
3. Apply cement to tube and install flanged wall fitting.
Make sure fitting is well seated and sealed (Figure 33).
4. Remove plaster frame from mounting bracket. Pull low
voltage wire through hole in bracket and insert bracket
into cutout. Secure bracket to flanged fitting with
4 screws provided. Be sure seal is secure between
flange fitting and mounting bracket (Figure 34).
18